Show simple item record

dc.contributor.advisorProf. Ir. Mochamad Teguh, MSCE., Ph.D.
dc.contributor.authorMuhammad Kurniawan Hidayat, 12 511 219
dc.date.accessioned2019-01-17T05:58:18Z
dc.date.available2019-01-17T05:58:18Z
dc.date.issued2018-12-03
dc.identifier.urihttps://dspace.uii.ac.id/handle/123456789/12903
dc.description.abstractOne of the requirements for earthquake resistant buildings is to use lightweight materials. This is because the magnitude of the earthquake inertia load is proportional to the weight of the building material. The use of brick as a wall in Indonesia is considered still not light because it has a weight of 2200 kg/m3 and 1700 kg/m3. The installation of both materials also requires a long time and a lot of labor. The development of construction technology provides a solution in the form of using foam to reduce the density of wall, and pre-cast technology to reduce the time and labor needed. However, the use of foam adds brittle properties to the walls, so it is necessary to strengthened with wire mesh. Therefore, research on the use of foam as a wall panel strengthened with wire mesh needs to be done to determine the best material composition and strength of the wall panel. Wall panel is a composite wall with a thickness of 12 cm, consisting of a layer of skin in the form of mortar and core layer in the form of foam concrete, strengthened with wire mesh with a diameter of 5 mm on the skin layer. The material composition of each layer was obtained through a compressive test using a cylindrical specimen with a diameter of 10 cm and a height of 20 cm. The mortar composition tested was 1PC:2PS, 1PC:3PS, and 1PC:4PS. The composition of foam concrete tested was 1PC:3PS with variations of foam additions as much as 40%, 50%, and 60%. The wall panel specimens amounted to 3 pieces for each test, with a size of 50x50x12 cm3 for compressive test, 100x50x12 cm3 for flexural test, and 120x120x12 cm3 for diagonal shear test. The compressive strength of the wall panels obtained were 15,414 MPa, 13,040 MPa and 14,394 MPa, respectively. The wall panel flexural strength obtained was 2,855 MPa, 2,925 MPa and 3,372 MPa, respectively. The diagonal shear strength of wall panels obtained were 1,464 MPa, 1,271 MPa, and 1,671 MPa, respectively. The initial damage mode for all wall panels is cracks between layers. In the flexural test, the subsequent damage is in the form of fracture of each layer, while in the shear test, the next damage is damage to the angle of the wall panel in the support area.en_US
dc.publisherUniversitas Islam Indonesiaen_US
dc.subjectWall panelsen_US
dc.subjectmortaren_US
dc.subjectfoam concreteen_US
dc.subjectwire meshen_US
dc.subjectfoamen_US
dc.subjectcompressive strengthen_US
dc.subjectflexural strengthen_US
dc.subjectdiagonal shear strengthen_US
dc.titlePENGGUNAAN BAHAN BUSA SEBAGAI PANEL DINDING DIPERKUAT DENGAN JARING KAWAT (THE USE OF FOAM AGENT AS A WALL PANEL STRENGTHENED WITH WIRE MESH)en_US
dc.typeUndergraduate Thesisen_US


Files in this item

Thumbnail
Thumbnail
Thumbnail
Thumbnail
Thumbnail
Thumbnail
Thumbnail
Thumbnail
Thumbnail
Thumbnail
Thumbnail
Thumbnail
Thumbnail
Thumbnail

This item appears in the following Collection(s)

Show simple item record