Evaluasi seismik struktur bangunan bertingkat dengan analisis statik nonlinier (Pushover) menggunakan program ETABS
Abstract
Lampung Province which is traversed by the Sumatran fault (Great
Sumatran Fault) which causes the potential for tectonic earthquakes to
occur, which is the location of the Multazam Building. So it is necessary
to evaluate the performance of the building structure. The purpose of this
study is to evaluate the existing Multazam Building in the Hajj Dormitory
area of Lampung Province against earthquake loads. The analysis method
in this study uses pushover analysis with reference to the ATC-40 (Applied
Technology council) method. From the analysis that has been done, the
base shear value for the x-direction capacity curve of 20105.37 kN is
greater than the y-direction capacity curve of 18823.68 kN. This shows
that the x direction is the strong axis of the building while the y direction
is the weak axis of the building. Next for the structural performance level
based on the maximum total drift parameter, the values for the x direction
is 0.005145 and the y direction is 0.005550, with the structural
performance level in the Immediate Occupancy (IO) category.
Furthermore, based on the maximum inelastic drift parameter, the value
for the x direction is 0.005078 and the y direction is 0.005483, with the
structural performance level in the Damage Control (DC) category. Then
for the plasticization process in the building under review begins with the
appearance of plastic joints in the beam section then in the column section
of the building. Based on the ATC-40 code, this is in accordance with the
beam sway mechanism criteria.