• Login
    View Item 
    •   DSpace Home
    • Lecturers And Researchers
    • Faculty of Civil Engineering and Planning
    • Department of Civil Engineering
    • Proceeding Civil Engineering Research Forum
    • 4th CE REFORM
    • View Item
    •   DSpace Home
    • Lecturers And Researchers
    • Faculty of Civil Engineering and Planning
    • Department of Civil Engineering
    • Proceeding Civil Engineering Research Forum
    • 4th CE REFORM
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Korelasi Hasil Uji Pendugaan Geolistrik Terhadap Hasil Standard Penetration Test

    Thumbnail
    View/Open
    Proceeding The 4th CeReform Final-473-484.pdf (615.8Kb)
    Date
    2023-02-15
    Author
    Sepliza, Ridiansyah
    Adi, Agus Darmawan
    Faris, Fikri
    Metadata
    Show full item record
    Abstract
    A This study aims to find a correlation between the results of the geoelectrical prediction test and the results of the standard penetration test (SPT). The geoelectrical prediction test in this study uses the Wenner method, and the standard penetration test (SPT) used is in accordance with ASTM D 1586-84. The method used in this study to obtain a correlation from the results of the geoelectrical prediction test to the results of the standard penetration test (SPT), namely the standard score using the Z-score and Tscore and the Pearson correlation test method. The results obtained from this study are the correlation of the results of the geoelectrical prediction test with the results of the standard penetration test (SPT). With the correlation of the results of the geoelectrical prediction test with the results of the standard penetration test (SPT), it is hoped that in the future the results of the geoelectric test can be used as a substitute for the standard penetration test (SPT) so as to streamline time and costs in soil investigation works. The correlation obtained from the results of the geoelectrical prediction test and the results of the standard penetration test using the Pearson method is 0.88 with a significance level of 7.83.
    URI
    http://hdl.handle.net/123456789/56186
    Collections
    • 4th CE REFORM [47]

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV