dc.description.abstractIndoor air pollution can be 2 to 10 times more dangerous than outdoor air pollution. One of the causes of indoor air pollution is pollutants or particles. In addition to pollutant particles, in terms of chemical parameters, namely carbon monoxide, carbon dioxide (CO and CO2) gas in certain levels can be harmful to health. Air that is absorbed in a room can be a place for the growth and reproduction of microorganisms, at a certain quantity of germs in the air can cause human respiratory infections. This study aims to determine indoor air quality in the Prawirotaman Market Parking Basement and map the distribution of PM10, CO, CO2 and Germ Count parameter concentrations with Surfer software. The method used for sampling PM10 parameters is gravimetric, for CO and CO2 parameters using direct reading, and for germ numbers using passive air sampling. The results of the study showed that all concentrations of PM10, CO, CO2 and germ numbers in the Prawirotaman Market Parking Basement did not exceed the quality standards of PerMenKes RI number 2 of 2023. Concentration mapping using Surfer Software is used to map the distribution of air pollutant concentrations with visualization using color differences that are used as identification of location points with higher levels of exposure to pollutants. Mapping of concentration results produces a distribution map with red color means high concentration while yellow, green, blue indicate lower concentration. The results of the mapping using surfer software show that the highest parameters of PM10 and germ count are at point 2, effective management is needed to prevent long-term increase in parameters by adding light and modifying circulation by adding ventilation in the charcoal seller's room. While the highest CO and CO2 parameter mapping is at point 3, from these results it is VII necessary to manage by adding exhaustfan in the motorcycle parking area and the market entrance in the north side.en_US
dc.publisherUniversitas Islam Indonesiaen_US
dc.subjectPM10en_US
dc.subjectCarbon Monoxideen_US
dc.subjectCarbon Dioxideen_US
dc.subjectGerm Counten_US
dc.titleAnalisis Kualitas Udara Parameter Pm10, Co, Co2 Dan Angka Kuman Pada Basemen Parkir Pasar Prawirotamanen_US
dc.typeThesisen_US
dc.Identifier.NIM20513272


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record