dc.description.abstractThe water pollution occurs due to the side product or waste produced by the VCO Industry is not properly managed. The waste water as the side product of VCO process happened since it is assumed that the water way system is used for waste water facility; the result of this makes most of the plants surrounding it found dead Inaddition, with the substandard construction of water ways for waste water causes the water polluted. The domestic waste using dual filtration of active carbon and kapok is used in this research. The objective of this research is toprove the capability and efficiency of dual media filtration reactor in reducing TSS concentration and oil grease in the liquid waste of VCO Industry. And also to prove if there is any variation change of TSS concentration reduction andoilgrease at each period of time against dual filtration of active carbon and kapok media. The research is done using dual bed filtration of active carbon and kapok which has 0.3 meter and 0.15 meter thickness with length and width 25 each, total height 108 cm. The waste water is kept inthe storage basin which is mixed with lime water. Then, the sample of waste water is run into the reactor which is gravitically dropped on the adsorbent (active carbon) then to kapok media. The variation of sample taking started from 0, 30, 60, 90, 120 and 150 minutes with debit 2,25 Lperminute. The sample taking of waste water was done at the outlet I (active carbon) and outlet II (kapok) then to be analyzed atLaboratory, for TSS parameter is inline with SK SNI M-03-1990-F quality test method of water physics, for grease oil Standard 62 test method of oil content and grease in the water gravitically SKSNIM-68-1990-03. Based on the result of laboratory analysis, it proves that there is a significant reduction of TSS concentration with average reduction efficiency 47.42% at the 90th minute till the 150th minute. For oil greaseconcentration goes on increasing with increase average efficiency 26.24% at the 90 till 150 thminute. This is because of the kapok hasreachedits highest level. Keywords: Domestic waste, VCO, TSS and fat oil.en_US
dc.publisherUniversitas Islam Indonesiaen_US
dc.subjectDomestic wasteen_US
dc.subjectVCOen_US
dc.subjectTSSen_US
dc.subjectfat oilen_US
dc.titlePenurunan Kadar TSS (Total Suspended Solid) dan Minyak Lemak (Fatoil) Limbah Cair pada Pengolahan VCO (Virgin Coconut Oil) dengan Filtrasi Menggunakan Bed Karbon Aktif dan Kapuken_US


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record